Temperatures
Cajun P550/P220 Command Line Interface Reference Guide
19-3
. ,
-
Set the shutdown temperature for a specific component of the Cajun switch. The default values are
listed in Table 28-2.
listed in Table 28-2.
Table 19-2.
Default Shutdown and Warning Temperatures
Table 19-3.
Parameters, Keywords, Arguments
Shutdown &
Warning
Temperatures
Warning
Temperatures
Shutdown
Upper
Lower
Warning
Warning
Low Limit
CPU Sensor
100°
85°
5°
0
°
All others
50°
45°
5°
0°
To Enable:
set temperature {supervisor-slot|backplane-sensor
|cpu-sensor|probe} shutdown <temperature>
Name
Definition
supervisor-slot|
backplane-sensor|
cpu-sensor|probe
backplane-sensor|
cpu-sensor|probe
These parameters indicate which component of the switch
is of interest.
is of interest.
shutdown
Shutdown is a required parameter and indicates that the
shutdown limit temperature is being set.
shutdown limit temperature is being set.
temperature
Temperature is a required parameter and when the switch
measures this value on this component, it shuts itself down
in order to prevent either inconsistent behavior or damage
to itself or surrounding equipment. The command checks
the entered temperature value and ensures that the
temperature being set is not above 127, and not below -128
degrees.
measures this value on this component, it shuts itself down
in order to prevent either inconsistent behavior or damage
to itself or surrounding equipment. The command checks
the entered temperature value and ensures that the
temperature being set is not above 127, and not below -128
degrees.