2-6
MDF/IDF DESIGN: SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES
LEGEND:
G— GREEN, NETWORK FIELD
Y — YELLOW, AUXILIARYY AND MISCELLANEOUS FIELD
W — WHITE. DISTRIBUTION FIELD
P — PURPLE EQUIPMENT FIELD
+— SPARE WITHOUT CROSS-CONNECT BLOCKS
G— GREEN, NETWORK FIELD
Y — YELLOW, AUXILIARYY AND MISCELLANEOUS FIELD
W — WHITE. DISTRIBUTION FIELD
P — PURPLE EQUIPMENT FIELD
+— SPARE WITHOUT CROSS-CONNECT BLOCKS
Figure 2-3. Six Type-1 Frames with 18,000-Pair Capacity
Type-2 Frame
The type-2 frame shown in figure 2-4, Seven Type-2 Frames with 16,800-Pair Capacity, is a special
frame with added jumper capacity. You can terminate 2400 pairs on each of its sides. Cross-
connections on the type-2 can be made either from top to bottom or from side to side, depending on the
frame with added jumper capacity. You can terminate 2400 pairs on each of its sides. Cross-
connections on the type-2 can be made either from top to bottom or from side to side, depending on the
size and shape of the installation.
Use the type-2 frame for large installations that require more than nine frames in a lineup.