3.2.1.4.1.   RECOMMENDED SAFETY STOP
With every dive over 10 meters the instrument has a three minute countdown for 
the recommended safety stop, to be taken in the 3 - 6 meter [10 ft - 20 ft] range. 
This is shown with the STOP sign and a three-minute countdown in the center 
window instead of the no-decompression time (Fig. 3.12.).
The Recommended Safety Stop, as the name implies, is recommended. If it is 
ignored, there is no penalty applied to the following surface intervals and dives.
3.2.1.4.2.   MANDATORY SAFETY STOP
When the ascent rate exceeds 12 meters/min [40 ft] momentarily or 10 meters/min 
[33ft] continuously the micro-bubble build-up is predicted to be more than allowed 
for in the decompression model. The Suunto RGBM calculation model responds 
to this by adding a Mandatory Safety Stop to the dive. The time of this Mandatory 
Safety Stop will depend on the severity of the ascent rate excess. 
The STOP sign will appear in the display and when you reach the depth zone 
between 6 m to 3 m [20 ft to 10] also the CEILING label, ceiling depth and 
the calculated Safety Stop time appear in the display. You should wait until the 
Mandatory Safety Stop warning disappears (Fig. 3.13.).
The Mandatory Safety Stop time always includes the three minute Recommended 
Safety Stop time. The total length of the Mandatory Safety Stop time depends on 
the seriousness of the ascent rate violation.