Nikon D4S Manuel D’Utilisation

Page de 500
420
n
❚❚ Manual Cleaning
If foreign matter can not be removed from the low-pass filter using 
the Clean image sensor (
0 417) option in the setup menu, the 
filter can be cleaned manually as described below. Note, however, 
that the filter is extremely delicate and easily damaged. Nikon 
recommends that the filter be cleaned only by Nikon-authorized 
service personnel.
1
Charge the battery or connect an AC adapter.
A reliable power source is required when inspecting or 
cleaning the low-pass filter. Turn the camera off and insert a 
fully-charged battery or connect an optional AC adapter and 
power connector. The Lock mirror up for cleaning option is 
only available in the setup menu at battery levels over J.
2
Remove the lens.
Turn the camera off and remove the lens.
3
Select Lock mirror up 
for cleaning.
Turn the camera on and 
press the 
G button to 
display the menus. 
Highlight Lock mirror up 
for cleaning
 in the setup 
menu and press 
2.
G button