Nikon D7000 Manuel D’Utilisation

Page de 348
286
n
❚❚“Manual Cleaning”
If foreign matter can not be removed from the low-pass filter using the Clean image 
sensor
 option in the setup menu (
0 284), the filter can be cleaned manually as 
described below. Note, however, that the filter is extremely delicate and easily 
damaged. Nikon recommends that the filter be cleaned only by Nikon-authorized 
service personnel.
1
Charge the battery or connect an AC adapter.
A reliable power source is required when inspecting or cleaning the low-pass 
filter. Turn the camera off and insert a fully-charged EN-EL15 battery or connect 
an optional EP-5B power connector and EH-5a AC adapter.
2
Remove the lens.
Turn the camera off and remove the lens.
3
Select Lock mirror up for cleaning.
Turn the camera on and press the 
button to display the menus. Highlight Lock 
mirror up for cleaning
 in the setup menu 
and press 
2 (note that this option is not 
available at battery levels of 
J or below).
4
Press 
J.
The message shown at right will be 
displayed in the monitor and a row of dashes 
will appear in the control panel and 
viewfinder. To restore normal operation 
without inspecting the low-pass filter, turn 
the camera off.
G button