Canon LV-7490 Brochure

Page de 74
LV-7490  Expand Serial Command Functional Specifications 
                                                                                   
                                                     
19  
 
 
8.4.5 CF_SHARP 
Command 
Command “CF_SHARP_%1”[CR] 
%1 
“000~015” ---------------- Directly select Sharpness setting value   
“UP” ------------------------ Current Sharpness setting value + 1 
“DN” ------------------------ Current Sharpness setting value - 1 
Details 
Set Sharpness value of user control 
Projector does not save the value set with this command so that it resets when 
projector turning into Standby status or ALL is OFF. (The value is held in Suspend 
mode.) 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.4.6 CF_GAMMA 
Command 
Command “CF_GAMMA_%1”[CR] 
%1 
“000~015” ---------------- Directly set Gamma setting value 
“UP” ------------------------ Current Gamma setting value + 1 
“DN” ------------------------ Current Gamma setting value – 1 
Details 
Set Gamma value of user control 
Projector does not save the value set with this command so that it resets when 
projector turning into Standby status or ALL is OFF. (The value is held in Suspend 
mode.) 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR]