9.11.24 CR_FANCONTROL  Command 
Command “CR_FANCONTROL”[CR] 
Details 
Get selected Fan control setting status 
Response 
Acceptable “000_%a”[CR] 
%a 
“OFF” ----------------------- Fan control is OFF 
“ON1” ----------------------- Fan control is ON1 
“ON2” ----------------------- Fan control is ON2 
Unacceptable  “Error Code” [CR] 
   
9.11.25 CR_ DELAYCTRL Command 
Command “CR_DELAYCTRL”[CR] 
Details 
Get setting status of Video delay control 
Response 
Acceptable “000_%1”[CR] 
%1 
“ON” ----------------------- Video delay control is active 
“OFF” ---------------------- Video delay control is inactive 
Unacceptable  
“Error 
Code”[CR] 
 
9.11.26   CR_FILH  Command 
Command “CR_FILH”[CR] 
Details 
Get Filter used time 
Response 
Acceptable “000_%1”[CR] 
%1 
“00000”~”99999” ------------------- 0 hour to 99999 hours 
Unacceptable  
“Error 
Code”[CR] 
   
9.11.27 CR_FILREPL  Command 
Command “CR_FILREPL”[CR] 
Details 
Get the information of Filter replacement time 
Response 
Acceptable “000_%1”[CR] 
%1 
“1Y” ------------------- Over filter replacement time 
“1N” ------------------ Within filter replacement time 
Unacceptable  
“Error 
Code”[CR] 
 
9.11.28   CR_FILTIMER Command 
Command “CR_FILTIMER” 
[CR] 
Details 
Get setting time which filter warning OSD is displayed 
Response 
Acceptable “000_%1”[CR] 
%1 
“1000” ----------------- 1000 hours 
“2000” ----------------- 2000 hours 
“3000” ----------------- 3000 hours 
“4000” ----------------- 4000 hours 
“5000” ----------------- 5000 hours 
“6000” ----------------- 6000 hours 
“OFF” ---------------- No OSD display 
Unacceptable  
“Error 
Code”[CR]