Canon DP-V3010 Manuel

Page de 104
32
Using the OSD Menu
Note
•  Due to the characteristic of LCD panel and individual difference of CA-310 and CA-210, the calibration results may differ.
•  Perform matrix calibration of the display color analyzer prior to calibration. If calibration is performed without performing
matrix calibration, an error may occur. Refer to the CA-310 and CA-210 instruction manual for the detail operation.
•  Warming-up is necessary to stabilize the brightness of the video display. Wait at least 10 minutes after turning on the power
before calibration.
•  Perform calibration in a dark room so that no external light enters the sensor. If external light enters the sensor, low
brightness characteristics cannot be calibrated correctly.
Export/Import
You can export/import LUT and CDL parameters as well as main menu settings. Insert a USB memory into the USB
port of the main unit.
 
LUT Import (
Setting is enabled except when "Canon Log (select "Color Gamut" → "ACESproxy")" or "ACESproxy" is selected for
"Picture Mode".
1.  Press the MENU button to open the OSD menu.
2.  Select "Adjustment"→"Detail Settings"→"LUT Import".
3.  Select a file.
In the "Filename" field, search and display a file with extension ".clut" in the root folder.
4.  Select the LUT type.
•  Select the LUT type by using "User LUT", "Gamma LUT" or "Gamut LUT".
•  Refer to the "Concept Drawing of Display Image Processing and LUT". Or, also refer to the "User LUT Creation
Guide" on the Canon website.
5.  In "Select LUT", select the destination to save the file.
Select User LUT/Gamma LUT/Gamut LUT 1-8.
6.  Select the standard color gamut.
Select the color gamut used when creating the LUT (when "Gamut LUT" under "LUT Type" is selected).
7.  Select "Execute".
When the confirmation screen appears, select "OK". Import starts.
Note
•  The LUT file is proprietary to Canon Video Display. Refer to the Canon website for the file format and how to create.
•  Up to 1000 LUT import files are recognized.
•  You can delete the imported LUT. You can specify the name of LUT (