OSD Menu
Item
Setting Options (underline indicates factory default)
Export/Import
Sets the export/import main menu settings.
Note
•  The following settings cannot be exported or imported.
Adjustment
Target values of Calibration (including calibration results)
Display Settings
Zoom, Frame Hold
Function Settings
Test Pattern, Various Function (Monochrome, Blue Only, Red Off, Green
Off, Blue Off, H Delay, V Delay)
System Settings
Date/Time, Export/Import, Power on Setting
•  User LUT data cannot be exported or imported to "User 1 to 3" under "Target".
•  Data exported from this product may not be imported to products of which firmware version
is earlier than the version of this product. To import data, update the firmware to the latest
version.
Export
Target: Select the export destination.
USB: Export to a USB memory.
User 1-3: Export to the built-in memory of the main unit.
Filename: Factory default is "dinfo.dat". You can change the name of the file to be exported to the
USB memory within 16 one-byte characters including alphabetical characters, numbers,
and symbols.
Execute: Performs export.
Import
Target: Specify the destination to save the file to be imported.
USB, User 1-3
Filename: Displays files with the extension ".dat" so you can select from among them.
Settings (All, Adjustment, Channel Settings, Display Settings, Marker Settings, Function 
Settings, System Settings)
: Select the settings to import.
Execute: Performs import.
Power on Setting
You can select the state of the display when the power is turned on.
Last memory: The video display starts up with the settings last used.
User 1-3: It starts up with the settings saved in "User 1-3" under "Export".
Reset All Settings
Returns all settings to factory default. When selected, the message "Reset all settings to factory
defaults?" appears.
OK: Performs reset.
Cancel: Returns to the previous screen without resetting.