Syslog 
290
ProSAFE M4100 Managed Switches 
Figure 29. Log message severity levels
The network administrator can adjust the urgent and non-urgent severity levels. These levels 
are global and apply to all destination email addresses. Log messages in the urgent group 
are sent immediately to the SMTP server with each log message in a separate mail. Log 
messages in the non-urgent group are batched into a single email message and after a 
configurable delay. 
Email alerting also provides a configuration option that allows the network administrator to 
specify the severity level at which SNMP traps are logged. Using this option, the 
administrator can put traps in the urgent group, the non-urgent group, or the never group for 
emailing. Traps are not emailed by default. For traps to be emailed, the network administrator 
has to either increase the severity at which traps are logged, or lower the severity level of log 
messages that are emailed.
The network administrator can configure multiple destination email addresses, and for each 
email address, specify whether to deliver urgent log messages, non-urgent log messages, or 
both. 
There is an exception to the sending of the messages periodically to the SMTP server. When 
the log buffer is completely full before the expiry of the periodic timer sending of the log 
messages to the SMTP server does not until the expiry of the timer. When the log buffer is 
full, a connection is opened immediately with the SMTP server, and all the messages that 
have not previously been emailed are sent to it.
CLI: Send Log Messages to admin@switch.com Using Account 
aaaa@netgear.com
1. 
Configure an SMTP server, for example, smtp.netgear.com. Before you configure the 
SMTP server, you need to have an account on SMTP server.
(Netgear Switch) (Config)#mail-server "smtp.netgear.com" port 465
(Netgear Switch) (Mail-Server)#security tlsv1 
(Netgear Switch) (Mail-Server)# username  aaaa 
(Netgear Switch) (Mail-Server)# password  xxxxxx
(Netgear Switch) (Mail-Server)#exit