Calibrating with the DocuColor12 Scanner
1.  Place the calibration form on the platen of the DocuColor 12 and click
Calibrate.
2.  If the calibration is successful, the screen display says, "The calibration
process was successful. You may now calibrate another media."
3.  Click OK to go back to the calibration window.
Note:  If the calibration process fails, check to make sure the test page is
properly positioned on the platen. The scanable area is 11"x 17". If the
calibration test form is outside this area, calibration will fail.
Calibrating with the Spectrocam™
1.  Place the test form and ruler on the black scanner plate and position the
measurement device on the first patch on the upper, left corner.
2.  Click on the Calibrate button.
If the Spectrocam was not previously calibrated, a prompt directs you to
calibrate the white reference. Place the measurement device on the white
target reference and touch the green sensor to calibrate. After calibrating with
the white reference, reposition the measurement device on the first patch on
the upper, left corner of the test form.
3.  Touch the green sensor and move the device slowly down the first row. When
you complete the first row, reposition the Spectrocam over the first patch of
the second row and touch the green sensor again to begin measuring the
second row. Continue in this fashion until all rows are read.
Important Note on Calibrating the Spectrocam™: Every Spectrocam™
needs to be calibrated against its own unique White Reference Target (an
absolute white point) before taking measurements. Take good care of your
Reference Target. For additional information, please see the Spectrocam™
user documentation.