Zanussi ZCG612H1XA Manuel D’Utilisation

Page de 32
Diametrele de bypass
ARZĂTOR
Ø BYPASS
1)
1/100 mm
Auxiliar
29 / 30
Semi-rapid
32
Rapid
42
Cuptor
44
1) Tipul de bypass depinde de model.
Arzătoare de gaz pentru GAZ NATURAL (de la reţea) G20 de 20 mbar
ARZĂTOR
PUTERE NOR‐
MALĂ ÎN kW
1)
PUTERE REDUSĂ kW
1)
MARCAJ INJECTOR
1/100 mm
Rapid
3.0
0.72 / 0.75
119
Semi-rapid
2.0 / 1.9
0.43 / 0.45
96
Auxiliar
1.0
0.35
70
Cuptor
2.7
0.90
120
Grătar
1.9
-
108
1) Tipul de bypass depinde de model.
Arzătoare de gaz pentru GPL G30 30 mbar
ARZĂTOR
PUTERE NOR‐
MALĂ ÎN kW
PUTERE RE‐
DUSĂ kW
MARCAJ INJEC‐
TOR 1/100 mm
DEBIT NOMINAL
PENTRU GAZ g/h
Rapid
3.0
0.72
88
218
Semi-rapid
2.0
0.43
71
145
Auxiliar
1.0
0.35
50
73
Cuptor
2.7
0.90
80
196
Grătar
1.9
-
71
138
Arzătoare de gaz pentru GPL G31 30 mbar
ARZĂTOR
PUTERE
NORMALĂ ÎN
kW
1)
PUTERE REDUSĂ
kW
1)
MARCAJ IN‐
JECTOR 1/100
mm
DEBIT NOMINAL
PENTRU GAZ g/h
Rapid
2.6
0.63
88
186
Semi-rapid
1.7
0.38
71
121
Auxiliar
0.85
0.31
50
61
www.zanussi.com
23