Cisco Cisco D9824 Advanced Multi Decryption Receiver Guide De Montage

Page de 416
 
Chapter 4    Front Panel Operation  
 
 
 
102 
 
Menu  Item 
Description 
Parameters 
Tones 
Sets  the three digit tone 
sequence. 
000 to  999 
Mode 
Sets  the tone  sequence mode. 
* - Start  tone  only 
# - End tone  only 
*/# - Start  and end tones. The  end 
tone  is signaled after  waiting  the time 
specified  in Delay(sec). 
Delay(sec) 
If  the Mode  was  set to  */# 
(Start/Stop),  set the delay, in 
seconds,  between the start  and 
stop  sequences. 
1 to 255. The default  is 30. 
Relay Mode 
The relay can be programmed 
to  respond  to  an alarm or 
warning  state, or  the state  of 
one of  the eight cue trigger 
pins. The response  is generated 
at the Cue Tone/Relay  output 
on the rear panel  of the 
receiver. 
Alarm or  Trigger 
The following  table displays  the 
possible  field  settings  and their 
relationship  to  the receiver output: 
Relay 
Mode 
Condition 
Relay 
Contact 
NC-
C-No 
Alarm  Unit Power 
Off 
Open
 
 
Close 
Alarm State  Open  Close 
No  Alarm 
Close  Open 
Trigger  Active 
(selected  in 
PNC) 
Close  Open 
Inactive 
Open  Close 
 
Cue Trigger Bit 
If  the Relay Mode  was  set to 
Trigger, select  the cue  trigger 
bit/pin that  will activate  the 
relay. 
1 to 8 
Cue Tone  Test 
Sets  the three digit cueing  tone 
test  sequence. 
000 to  999 
Mode 
Sets  the test  sequence mode. 
* - Start  tone   
# - End tone 
Run Test 
Select  and press  continue  to run 
the cue  tone test  according  to 
the Cue Tone  Test  and Mode.