Cisco Cisco 2600 3600 3700 Series 36-Port 10 100 EtherSwitch Modules Guide De Dépannage

Page de 92
   
2-27
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem System Message Guide
380260-002
Chapter 2      Message and Recovery Procedures
HARDWARE Messages
Error Message GBIC_SECURITY_UNIQUE-4-DUPLICATE_SN: GBIC interface [dec]/[dec] has 
the same serial number as another GBIC interface.
Explanation
This message means that the SFP module was identified as a Cisco SFP module, but its 
serial number matches that of another interface on the system. [dec]/[dec] is the interface in which 
the duplicate module is installed.
Recommended Action
Cisco SFP modules are assigned unique serial numbers. Verify that the module 
was obtained from Cisco or from a supported vendor.
HARDWARE Messages
This section contains hardware messages.
Error Message HARDWARE-1-THERMAL_CRITICAL: Temperature has reached critical 
threshold. 
Explanation
This message means that the temperature sensor valve inside the switch reached the 
critical threshold. The switch is unable to function normally. 
Recommended Action
The external temperature is very high. Immediately reduce the temperature in 
the room. Check for fan fault.
Error Message HARDWARE-2-FAN_ERROR: Fan Failure.
Explanation
This message means that the fan is not working. 
Recommended Action
This is a hardware failure. The fan might recover automatically. If the fan 
failure persists, copy the message exactly as it appears on the console or in the system log. Research 
and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for 
similar reported problems. If you still require assistance, contact HP technical support and provide 
the representative with the gathered information. For more information about the online tools and 
about contacting HP, see the 
Error Message HARDWARE-2-THERMAL_WARNING: Temperature has reached warning threshold.
Explanation
This message means that the temperature sensor valve inside the switch reached the 
warning threshold. The switch can function normally until the temperature reaches the critical 
threshold. 
Recommended Action
The external temperature is high. Reduce the temperature in the room.