Cisco Cisco Prisma II EDR Receiver Guide De Montage

Page de 178
 
Appendix A 
Module Parameter Descriptions 
146 
 
Alarm Parameters 
 
Parameter 
Name (LCI) 
ICIM 
Abbreviation 
Description 
Major 
Low 
Minor 
Low 
Minor 
High 
Major 
High 
Operating 
Range 
Power 
Supply 
Status 
PsOk 
Alarm if +24 or -5V fails 
OK or 
Alarm 
Rx1_LOS
1
 
Rx2_LOS
Rx3_LOS
Rx4_LOS
1
 
Loss of Node optical signal 
for Rx1 to Rx4 
-18.0 
dB Std 
-25 dB 
Ext 
-15.0 
dB 
-10.0 
dB 
-8.0 
dB 
OK or 
Alarm 
Rx 1 Loss of 
Data
1
 
Rx 2 Loss of 
Data
Rx 3 Loss of 
Data
Rx 4 Loss of 
Data
1
 
Rx1_Data 
Rx2_Data 
Rx3_Data 
Rx4_Data 
Loss of data for Rx1 to Rx4 
OK or 
Alarm 
Internal 
Communicati
on Status 
IntComm 
Internal communication 
error 
OK or 
Alarm 
Forced Alarm 
Status 
Alarm 
Manual alarm state 
OK or 
Alarm 
Node Data 
Valid 
NodeData 
Node data valid or invalid 
OK or 
Alarm 
Note: All parameters below this point in the table relate to the attached node and are monitor-only. 
Tx Power 
Status 
NdTxPwr 
Output power alarm for 
transmitter 
OK or 
Alarm 
Rx Power 
Status 
NdRxPwr 
Output power alarm for 
receiver 
OK or 
Alarm 
EDR Optical 
Level 
 
 
1 dBm  2 dBm  8 dBm  9dBm   
 
 
1.3 
mW 
1.6 
mW 
6.3 
mW 
7.9 