Cisco Cisco Prisma II EDR Receiver Guide De Montage
Appendix A
Module Parameter Descriptions
Module Parameter Descriptions
156
Alarm Parameters
Parameter
Name (LCI)
Name (LCI)
ICIM
Abbreviation
Abbreviation
Description
Major
Low
Low
Minor
Low
Low
Minor
High
High
Major
High
High
Operating
Range
Range
Power
Supply
Status
Supply
Status
PsOk
Alarm if +24 or -5V fails
-
-
-
-
OK or
Alarm
Alarm
-
Rx1_LOS
1
Rx2_LOS
1
Rx3_LOS
1
Rx4_LOS
1
Loss of Node optical signal
for Rx1 to Rx4
for Rx1 to Rx4
-18.0
dB Std
-25 dB
Ext
dB Std
-25 dB
Ext
-15.0
dB
dB
-10.0
dB
dB
-8.0
dB
dB
OK or
Alarm
Alarm
Rx 1 Loss of
Data
Data
1
Rx 2 Loss of
Data
Data
1
Rx 3 Loss of
Data
Data
1
Rx 4 Loss of
Data
Data
1
Rx1_Data
Rx2_Data
Rx3_Data
Rx4_Data
Rx2_Data
Rx3_Data
Rx4_Data
Loss of data for Rx1 to Rx4
-
-
-
-
OK or
Alarm
Alarm
Internal
Communicati
on Status
Communicati
on Status
IntComm
Internal communication
error
error
-
-
-
-
OK or
Alarm
Alarm
Forced Alarm
Status
Status
Alarm
Manual alarm state
-
-
-
-
OK or
Alarm
Alarm
Node Data
Valid
Valid
NodeData
Node data valid or invalid
-
-
-
-
OK or
Alarm
Alarm
Note: All parameters below this point in the table relate to the attached node and are monitor-only.
-
NdRx1LOS
NdRx2LOS
NdRx2LOS
Loss of signal in Rx1 or Rx2 -
-
-
-
OK or
Alarm
Alarm
-
NdLidStat
1
Status of node lid
(open/closed)
(open/closed)
-
-
-
-
OK or
Alarm
Alarm
1
Alarm threshold values can be modified by the user using the ICIM2 or ICIM2-XD, LCI
software, ROSA software, CLI commands, or the ICIM Web Interface.