Cisco Cisco D9824 Advanced Multi Decryption Receiver Guide De Montage

Page de 336
 
Chapter 4    Front Panel Operation 
 
 
 
108 
78-4039426-01 Rev D 
Menu Item 
Description 
Parameters 
Alarm Vid Cutoff 
Select whether the video output 
is cut off if any enabled alarm is 
active on the receiver. When 
video is cut off, there will be no 
horizontal or vertical 
synchronization on the output. 
This is useful for downstream 
redundancy switching by 
detecting a loss of video signal.  
Note: This function also exists 
under Setup: Services: Video. 
Enable or Disable 
The default is Disable. 
System 
Alarm/Warning 
Name 
Displays the alarm or warning 
to configure. 
 
Enb 
Select whether the current 
alarm is enabled or disabled. If 
the alarm is disabled, the Rly 
and Trp settings are ignored 
Yes or No 
Rly 
If the current alarm or warning 
is enabled (Enb is set to Yes), 
select whether it will trigger the 
rear panel relay when the alarm 
is set or cleared. 
Yes or No 
Note: No is a read only value that 
indicates the setting is Yes, but is 
currently being suppressed because 
the alarm or warning is disabled (Enb 
is set to No). 
Trp 
If the current alarm or warning 
is enabled (Enb is set to Yes), 
select whether it will send 
SNMP trap messages when the 
alarm is set or cleared. 
Yes or No 
Note: No is a read only value that 
indicates the setting is Yes, but is 
currently being suppressed because 
the alarm or warning is disabled (Enb 
is set to No).