Cisco Flexible Solutions Taps Fiche De Données

Page de 9
Surge-Gap Taps -- Two-Way, Four-Way, Eight-Way 
Standard & Full Profile
 
 
4
 
 
Specifications, continued 
 
2-Way Surge Gap Tap – Full Profile Housing 
 
Tap Value 
11 
14 
17 
20 
23 
26 
29 
 
 
Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ.
Frequency                   
5 - 
3.2 
2.8
2.0 1.7
1.2
1.0
1.1
0.7 0.8
0.5 0.7 0.5 0.6 0.5
0.6 0.3
55 - 
2.5 
2.2
1.4 1.2
0.9
0.7
0.7
0.5 0.7
0.4 0.6 0.4 0.6 0.4
0.9 0.3
550 - 
3.6 
3.2
2.5 2.0
1.8
1.5
1.6
1.3 1.4
1.1 1.4 1.1 1.4 1.1
1.3 1.0
650 - 
3.6 
3.4
2.7 2.2
2.0
1.6
1.6
1.3 1.4
1.1 1.4 1.1 1.5 1.1
1.3 1.1
750 - 
4.1 
3.5
2.8 2.4
2.1
1.8
1.7
1.4 1.5
1.2 1.5 1.2 1.6 1.2
1.4 1.2
870 - 
4.2 
3.7
3.2 2.6
2.4
2.1
1.9
1.6 1.7
1.4 1.6 1.3 1.7 1.4
1.6 1.4
Insertion 
Loss  
(In-Out) 
(dB) 
1000 - 
4.5 
3.8
3.5 2.9
2.7
2.5
2.2
1.8 2.0
1.6 1.8 1.6 1.9 1.6
1.9 1.7
 
 
 
Tap Value 
11 
14 
17 
20 
23 
26 
29 
Frequency 
         
1.0 1.0 1.2 1.3 1.3 1.5 1.3 1.0 1.4 
55  1.0 1.1 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
550  1.0 1.3 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
650  1.0 1.3 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
750  1.0 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
870  1.0 1.7 1.0 1.0 1.0 1.0 1.0 1.0 1.0 
Tap Loss 
Tolerance  
 (
± dB) 
1000 1.5 2.1 1.3 1.2 1.1 1.1 1.0 1.0 1.4 
5-50 - 20 19 22 26 32 31 40 38 
51-550 -  26 27 30 34 35 38 41 41 
551-650 -  23 30 28 37 33 39 39 38 
651-750 -  22 33 26 33 32 38 37 37 
751-870 -  20 27 24 33 30 35 35 35 
Out-Tap 
Isolation 
(Min.)  
(dB) 
871-1000 -  20 24 23 31 27 31 32 33 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, the above specifications reflect typical performance.  Unless otherwise noted, specifications are based on 
measurements made in accordance with NCTA Recommended Practices for Measurements on Cable Television Systems and are 
referenced to 68
° F (20° C).