Cisco Cisco Content Security Management Appliance M1070 Mode D'Emploi

Page de 450
 
9-4
AsyncOS 9.6 for Cisco Content Security Management Appliances User Guide
 
Chapter 9      Managing Web Security Appliances
  Setting Up Configuration Masters to Centrally Manage Web Security Appliances
Note
The Configuration Master version should match the AsyncOS version on the Web Security appliance, as 
specified in the Compatibility Matrix. Publishing an older Configuration Master version to a newer Web 
Security appliance may fail if settings on the Web Security appliance do not match the settings in the 
Configuration Master. This can occur even if the Web Appliance Status detail page does not indicate any 
discrepancies. In this case, you must manually compare the configurations on each appliance. 
Enabling Centralized Configuration Management on the Security Management 
Appliance
Procedure 
Step 1
On the Security Management appliance, choose Management Appliance > Centralized Services > 
Web > Centralized Configuration Manager
.
Step 2
Click Enable.
Step 3
If you are enabling Centralized Configuration Management for the first time after running the System 
Setup Wizard, review the end user license agreement, and click Accept.
Step 4
Submit and commit your changes. 
Initializing Configuration Masters 
Note
After you initialize a configuration master, the Initialize option is not available. Instead, populate the 
Configuration Master using one of the methods described in 
Procedure 
Step 1
On the Security Management appliance, choose Web > Utilities > Configuration Masters
Step 2
Click Initialize in the Options column.
Step 3
On the Initialize Configuration Master page: 
If you have an existing Configuration Master for a previous release and you want to use or start with 
the same settings for the new Configuration Master, choose Copy Configuration Master
You can also import settings from an existing Configuration Master later. 
Otherwise, choose Use default settings
Step 4
Click Initialize.
The Configuration Master is now available. 
Step 5
Repeat for each Configuration Master version to initialize.