Cisco Cisco Content Security Management Appliance M1070 Mode D'Emploi

Page de 450
 
14-13
AsyncOS 9.6 for Cisco Content Security Management Appliances User Guide
 
Chapter 14      Common Administrative Tasks
  Backing Up Security Management Appliance Data
The phases of the backup process and their effect on the availability of services are as follows:
Phase 1—Phase 1 of the backup process starts with the data transfer between the source and target 
appliances. During data transfer, services on the source appliance remain running, therefore data 
collection can still continue. However, services are shut down on the target appliance. Once the data 
transfer is complete from the source to target appliance, Phase 2 begins.
Phase 2—When Phase 2 begins, services on the source appliance are shut down. Any differences 
that have collected during the data transfer between the source and target appliance since the initial 
shutdown are copied to the target appliance and services on both the source and the target appliances 
are returned to the state they were in when backup was initiated. This allows maintain maximum 
uptime on the source appliance and no data loss for either appliance. 
During the backup, data availability reports may not work, and when viewing the message tracking 
results, the hostname for each message may be labeled as ‘unresolved’. 
If you try to schedule a report and forget that a backup is in progress, you can check the system status 
by choosing Management Appliance > Centralized Services. From this window you can see the 
warning at the top of the page that a system backup is in progress. 
Interruption of a Backup Process 
Note
If there is an unexpected reboot of the source appliance while a backup is being performed, the target 
appliance is unaware of this stoppage. You must cancel the backup on the target appliance.
If there is an interruption of the backup process and the backup process is not completed, the next time 
a backup is attempted, the Security Management appliance can start the backup process up from where 
it was stopped. 
Canceling a backup in progress is not recommended, as the existing data will be incomplete and may not 
be usable until a subsequent backup is completed, especially if you receive an error. If you must cancel 
a backup in progress, be sure to run a complete backup as soon as possible to ensure that you always 
have a usable current backup. 
Prevent the Target Appliance From Pulling Data Directly from Managed 
Appliances 
Step 1
Access the command-line interface of the target appliance. For instructions, see 
Step 2
Run the 
suspendtransfers
 command. 
Step 3
Wait for the prompt to reappear. 
Step 4
Run the 
suspend
 command. 
Step 5
Wait for the prompt to reappear. 
Step 6
Exit the command-line interface of the target appliance.