Chapter 8      Centralized Management
8-492
Cisco IronPort AsyncOS 7.3 for Email Advanced Configuration Guide
OL-23081-01
command. You can have two separate clusters running while you upgrade 
machines to the same version. You can also upgrade clustered machines on the 
GUI Upgrades page.
Note
If you use the upgrade command before disconnecting the individual machine 
from the cluster, AsyncOS disconnects all the machines in the cluster. IronPort 
Systems recommends that you disconnect each machine from the cluster before 
upgrading it. Then, other machines can continue working as a cluster until each is 
disconnected and upgraded.
To upgrade the machines in a cluster via the CLI:
Step 1
On a machine in the cluster, use the 
disconnect
 operation of 
clusterconfig
. For 
example, to disconnect the machine 
losangeles.example.com
, type 
clusterconfig 
disconnect
 
losangeles
.example.com
. No 
commit
 is 
necessary.
Step 2
Optionally, use the 
suspendlistener
 command to halt acceptance of new 
connections and messages during the upgrade process.
Step 3
Issue the 
upgrade
 command to upgrade AsyncOS to a newer version.
Note
Disregard any warnings or confirmation prompts about disconnecting all 
of the machines in the cluster. Because you have disconnected the 
machine, AsyncOS does not disconnect the other machines in the cluster 
at this point.
Step 4
Select the version of AsyncOS for the machine. The machine will reboot after the 
upgrade is complete.
Step 5
Use the 
resume
 command on the upgraded machine to begin accepting new 
messages.
Step 6
Repeat steps 1 - 5 for each machine in the cluster.
Note
After you disconnect a machine from the cluster, you cannot use it to 
change the  configurations of other machines. Although you can still 
modify the cluster configuration, do not change it while machines are 
disconnected because settings can become unsynchronized.