Cisco Cisco Aironet 340 Ethernet Bridges Mode D'Emploi

Page de 218
Setting Up Event Logs   12 - 7
Lost our association, new specified router
The specified router parameter of this repeater has been changed. The 
unit will drop its current association and try to re-associate.
Lost our association, NAK from router
The unit responds as though it was associated to its parent, however, the 
parent does not have the association. The unit will attempt to re-associ-
ate. The parent may have been rebooted.
No response to radio loopback test
The "config radio extended test" command was set on and no bridge in 
range responded to the loopback test. If you know there are units in 
range, then either the local radio has failed, or if there is only one 
remote in range, then the remote unit’s radio may have failed.
Radio Configuration Error nn
The Aironet 340 Series Bridge could not program the radio hardware to 
operate at the correct frequency and bit rate. Have the unit serviced.
Radio loopback test succeeded
After having failed, the radio loopback test heard a response from a 
remote.
The address PROM is invalid
Each unit contains a Programmable Read-Only Memory (PROM) chip 
that contains the unit’s hardware address. During power up, the unit was 
not able to read a valid address from the PROM. The unit must be
serviced.