Cisco Cisco Aironet 340 Ethernet Bridges Mode D'Emploi
Setting Up Event Logs 12 - 11
Setting Statistic Parameters (Statistics)
This command allows you to control how alarms are generated based on
any of the available statistics kept by the bridge. Logs may be:
any of the available statistics kept by the bridge. Logs may be:
n Disabled for statistics
n Generated if the statistic changes at all
n Generated if the statistic changes at a greater than specified rate
Í To Set Statistic Parameters:
1.
Select statistics. Type a number or the short form.
1. ra Radio
2. re Radio error
Enter one of [a number from 1 to 2, a short form]:
2.
You will be prompted for the statistics category. Enter the number or
the short form. The short form is used to store the command in the
configuration.
configuration.
3.
Type a category number or the short form and press ENTER.
4.
Choose the particular statistics that you wish to change. If any of the
statistics already have an alarm associated, the current setting is dis-
played after the name.
played after the name.
Enter an action, one of [off, any, rate]:
Radio
Receive Transmit
1 rpa Packets 5 tpa Packets
2 rby Bytes
6 tby Bytes
3 rfi Filtered 7 ter Errors
4 rer Errors
Enter one of [a number from 1 to 7, a short form]: