Cisco Cisco TelePresence MX700 Fascicule
330: How do I install the MultiSite option key?
Incoming MultiSite Call is allowed as a default setting. If the Incoming MultiSite Call is disabled,
it can be turned back on.
Follow the instructions below to turn on Incoming
Follow the instructions below to turn on Incoming
MultiSite Call option using the web interface:
1. Enter the IP address of your codec on a web browser
2. Select
Configurations
>
System Configuration
.
3. Select
Conference
from the menu on the left.
4. In the scroll down menu for
IncomingMultisiteCall Mode select Allow.
Follow the instructions below for using the web interface:
1. Enter the IP address of your codec on a web browser
2. Select
Maintenance
>
Option Key
.
3. Reboot the codec.
Applies to the following products:
y
SX20 Quick Set
y
SX80
y
Codec C40
y
Codec C60
y
Codec C90
y
MX200
y
MX300
y
MX200 G2
y
MX300 G2
y
MX700
y
MX800
y
EX90
Related questions:
329: Why can I only place point-to-point calls on my codec?
611: Can I run MultiSite on EX and MX video systems?
332: I installed a second PrecisionHD 1080p Camera on my C Series codec, but I am unable
to control it. Why?
To control the second camera you need to use a VISCA cascading cable. The VISCA cascad-
ing cable connects the first camera to the second camera and can be ordered from Cisco.
You need to configure the video input source to set which camera you should control, when
this particular video input source is active:
1. Login to the codec as
admin using SSH (Secure Shell).
2. To configure the second camera to be connected to video input source 2, run the
following API command:
xConfiguration Video Input Source 2 CameraControl CameraId: 2
Applies to the following products:
y
Codec C40
y
Codec C60
y
Codec C90
333: I installed a video camera to the video input number 2 on my C90 using component video,
now I am not able to get any video when I activate this source. Why?
A C90 codec can connect up to 12 HD video input sources, but only five can be active
simultaneously. As default the video input source number 2 is set to be HDMI. You can find
more information on the video input sources in the Administrator Guide for the C90 codec.
To change this, open the
Home
menu on the C90 codec and go to:
Settings > Administrator
settings > Advanced configuration > Video > Input > Source 2
and set the
Connector
to
YPbPr
.
Applies to the following products:
y
Codec C90
363: Is transcoding supported for the H.239/dual stream?
No, the H.239/dual stream does not support transcoding. Therefore, the dual stream capability
in an internal MultiSite is restricted by the common denominator.
Applies to the following products:
y
SX20 Quick Set
y
Codec C20
y
Codec C40
y
Codec C60
y
Codec C90
y
MX200
y
MX300
y
EX60
y
EX90
Cisco TelePresence TC Endpoints
D14865.03 TC Endpoints Knowledge Base Articles | APRIL 2015
Copyright © 2011–2013 Cisco Systems, Inc. All rights reserved.
15
Knowledge Base Articles
Contents
Introduction
Questions
Contact
Questions and answers
Appendices
Questions and answers