Cisco Cisco Packet Data Gateway (PDG) Guide De Dépannage

Page de 192
PDN Gateway Overview   
▀  How the PDN Gateway Works 
 
▄  Cisco ASR 5000 Series Packet Data Network Gateway Administration Guide 
OL-22985-01   
Figure 14.  Subscriber-initiated Detach Call Flow 
Delete 
Bearer Rsp
PCRF 
Interactions
Delete 
Bearer Rsp
Delete 
Bearer Req
eNodeB
MME
S-GW
UE
P-GW
PCRF
HSS
1
2
Detach Request
5
Delete 
Bearer Req
3
4
6
Detach Response
Signaling 
Connection Rel
8
7
 
 
Table 8. Subscriber-initiated Detach Call Flow Description 
Step
 
Description
 
1
 
The UE sends NAS message Detach Request (GUTI, Switch Off) to the MME. Switch Off indicates whether detach is due 
to a switch off situation or not.
 
2
 
The active EPS Bearers in the S-GW regarding this particular UE are deactivated by the MME sending a Delete Bearer 
Request (TEID) message to the S-GW.
 
3
 
The S-GW sends a Delete Bearer Request (TEID) message to the P-GW.
 
4
 
The P-GW acknowledges with a Delete Bearer Response (TEID) message.
 
5
 
The P-GW may interact with the PCRF to indicate to the PCRF that EPS Bearer is released if PCRF is applied in the 
network.
 
6
 
The S-GW acknowledges with a Delete Bearer Response (TEID) message.
 
7
 
If Switch Off indicates that the detach is not due to a switch off situation, the MME sends a Detach Accept message to the 
UE.
 
8
 
The MME releases the S1-MME signalling connection for the UE by sending an S1 Release command to the eNodeB with 
Cause = Detach.