Mounting the Access Point
Step 4
Cut the cables to length, install F-connectors on the ends, and connect them to the grounding block.
Caution
To prevent damage to the access point or power injector, connect all coax cables from the 
power injector to the access point and connect the power jack to the power injector before 
applying power.
Note
The grounding block must be connected to the building's grounding electrode system by 
14 AWG copper wire or larger.
Step 5
Find the building's grounding electrode system and then connect the access point ground lug to it using 
6 AWG copper wire. Use a crimping tool to crimp the wire to the ground lug. For more information about 
attaching the ground lug to the access point, see 
 in the 
 for the ground lug location.
Caution
To ensure correct installation and grounding, install the access point in compliance with your 
local and national electrical codes: National Fire Protection Association (NFPA) 70, National 
Electrical Code (U.S.); Canadian Electrical Code, Part I, CSA 22.1 (Canada); and if local or 
national electrical codes are not available, refer to IEC 364, Part I through Part 7 (other 
countries).
Note
Local code may require grounding of the rooftop mount.
Step 6
For outdoor locations, weather seal all coaxial connectors by wrapping them with the sealant tape 
provided with the installation kit. For more information, see the 
.
Tower Mount
A professional installer must install the access point on a tower. A professional installer has skills and 
knowledge related to the construction, operation, and installation of electrical equipment and has 
received safety training on the hazards involved.
Installing the access point on a tower includes the following subtasks:
1.
Mounting the access point
2.
Routing the cables (normal or lightning protected)
3.
Activating the link
This warning applies to outdoor access point installations.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 
Statement 1030