Cisco Cisco Tunnel Terminating Gateway (TTG)

Page de 421
  Troubleshooting 
Detecting Faulty Hardware  ▀   
 
ASR 5500 System Administration Guide, StarOS Release 18  ▄  
 
   
197 
SSC System Service LED States 
The System Service LED on the SSC illuminates amber to indicate that the system has experienced a hardware 
component failure. 
This LED is off during normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 33.  SSC System Service LED States 
Color
 
Description
 
Troubleshooting
 
Amber
 
System requires maintenance (fan filter, 
temperature warning, PFU outage etc.).
 
Monitoring the System for show commands, the outputs of which 
will assist in further determining the problem.
 
Refer to System Logs for information on how to view logs.
 
None
 
No component failures have been detected. 
OR 
Card is not receiving power. 
No maintenance needed.
 
 
Testing System Alarm Outputs 
The system provides the following two physical alarm mechanisms: 
 
System Audible Alarm: Located on the SSC, the speaker is used to provide an audible indicator that a minor, 
major, or critical alarm has occurred. 
 
CO Alarms Interface: Located on the SSC, this interface provides a DB-15 connector that enables three dry-
contact relays (Form C) for the triggering of external audio and/or visual indicators. These indicators can be 
used to alert that either a minor, major, or critical alarm has occurred. 
The operation of these alarms can be tested by issuing the following command: 
[local]host_nametest alarm { audible | central-office [ critical | major | 
minor ] }
 
When this command is executed, the specified alarm is activated for a period of 10 seconds. After this time, the alarm 
will return to its previous condition.