Cisco Cisco Packet Data Gateway (PDG)

Page de 1824
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm model,
the system assumes it is identical to the high threshold.
Important
You must enter a value between 1 and 100000 to trigger an alert/alarm.
Important
Usage Guidelines
Use this command to set an alert or an alarm when the number of registration reply errors is equal to or greater
than a specified number of calls per second.
Alerts or alarms are triggered for the number of registration reply errors on the following rules:
• Enter condition: Actual number of registration reply errors > High Threshold
• Clear condition: Actual number of registration reply errors £ Low Threshold
Examples
The following command configures a registration reply error threshold of 1000 and a low threshold of 500
for a system using the Alarm thresholding model:
threshold reg-reply-error 1000 clear 500
   Command Line Interface Reference, Modes E - F, StarOS Release 19
1648
FA Service Configuration Mode Commands
threshold reg-reply-error