Cisco Cisco ASR 5700
Global Configuration Mode Commands (T-threshold phspc)
threshold dcca-unknown-rating-group ▀
Command Line Interface Reference, StarOS Release 17 ▄
5599
threshold dcca-unknown-rating-group
Configures alarm or alert thresholds for the unknown Diameter Credit Control Application (DCCA) Rating Group
(content-id) messages returned by Diameter servers.
(content-id) messages returned by Diameter servers.
Product
ACS
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold dcca-unknown-rating-group high_thresh [ clear low_thresh ]
default threshold dcca-unknown-rating-group
default
Disables the threshold for configured alarm and sets the
high_thresh
and
low_thresh
values to 0.
high_thresh
Default: 0
Specifies the high threshold number of unknown Rating Group (content-id) messages sent by the Diameter
server that must be met or exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold number of unknown Rating Group (content-id) messages sent by the Diameter
server that must be met or exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 1000000.
clear
low_thresh
Default: 0
Specifies the low threshold number of unknown Rating Group (content-id) sent by Diameter server and
received by system that maintains a previously generated alarm condition. If the number of errors falls
beneath the low threshold within the polling interval, a clear alarm will be generated.
Specifies the low threshold number of unknown Rating Group (content-id) sent by Diameter server and
received by system that maintains a previously generated alarm condition. If the number of errors falls
beneath the low threshold within the polling interval, a clear alarm will be generated.
low_thresh
is an integer from 0 through 1000000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
In the event that the Diameter server sends invalid Rating Groups, content-ids to the system, dcca-unk-
rating-group message is generated.
Unknown Rating Group threshold generates alerts or alarms based on the number of unknown Rating Groups
received by the system from Diameter server during the specified polling interval.
rating-group message is generated.
Unknown Rating Group threshold generates alerts or alarms based on the number of unknown Rating Groups
received by the system from Diameter server during the specified polling interval.