Cisco Cisco Tunnel Terminating Gateway (TTG)
HNBGW-RANAP Schema Statistics
Common Syntax Options ▀
Statistics and Counters Reference, StarOS Release 18 ▄
993
Variables
Description
Data Type
ps-srns-back-class-rab-setup-rx
PS Domain: Indicates the total number of SRNS Data Fwd
Command message transmitted for Background Class for RAB
Setup.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Background Class for RAB Setup.
Availability: Across all HNB-GW Services
Command message transmitted for Background Class for RAB
Setup.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Background Class for RAB Setup.
Availability: Across all HNB-GW Services
Unsigned
Int32
Int32
ps-srns-back-class-rab-setup-local-fail
PS Domain: Indicates the total number of SRNS Data Fwd
Command message transmitted for Background Class for RAB
Setup/Local Failure.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Background Class for RAB Setup/Local Failure.
Availability: Across all HNB-GW Services
Command message transmitted for Background Class for RAB
Setup/Local Failure.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Background Class for RAB Setup/Local Failure.
Availability: Across all HNB-GW Services
Unsigned
Int32
Int32
ps-srns-unkwn-class-rab-setup-rx
PS Domain: Indicates the total number of SRNS Data Fwd
Command message transmitted for Unknown Class for RAB
Setup.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Unknown Class for RAB Setup.
Availability: Across all HNB-GW Services
Command message transmitted for Unknown Class for RAB
Setup.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Unknown Class for RAB Setup.
Availability: Across all HNB-GW Services
Unsigned
Int32
Int32
ps-srns-unkwn-class-rab-setup-local-fail
PS Domain: Indicates the total number of SRNS Data Fwd
Command message transmitted for Unknown Class for RAB
Setup/Local Failure.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Unknown Class for RAB Setup/Local Failure.
Availability: Across all HNB-GW Services
Command message transmitted for Unknown Class for RAB
Setup/Local Failure.
Trigger: When SRNS Data Fwd Command message is transmitted
by HNB-GW for Unknown Class for RAB Setup/Local Failure.
Availability: Across all HNB-GW Services
Unsigned
Int32
Int32
Important:
For information on statistics that are common to all schema see the Statistics and Counters Overview
chapter.