Cisco Cisco 1 GHz GainStar Node Guide De Montage
Attaching the Coaxial Connectors
OL-31947-02
15
To Connect the RF Connector Pin
Complete the following steps to connect the RF connector pin to the GainStar Mini
Node housing.
1 Start this procedure with the GainStar Mini Node housing open. Refer to
Node housing.
1 Start this procedure with the GainStar Mini Node housing open. Refer to
Opening the Mini Node Housing.
2 If the center conductor pin extends beyond the STRIP line on the housing, trim
the pin with heavy-duty wire cutters.
3 If the RF connector is PG11, go to Step 4. If the RF connector is 5/8”, screw the
RF cable connector adapter onto the housing before proceeding to Step 4.
4 Insert the appropriate RF connector into the desired RF port. Tighten the
connector nut according to manufacturer specifications.
5 Tighten the RF F-Cable connector bolt from 0.9 Nm to 1.0 Nm.
6 Repeat steps 2 through 4 for each RF port used.
7 Proceed to Installing the Housing.
6 Repeat steps 2 through 4 for each RF port used.
7 Proceed to Installing the Housing.