Cisco PowerKEY CableCARD Module 805 Mode D'Emploi

Page de 57
 
 
Identifying Error Handling Conditions 
4014667 Rev C 
31 
 
Error  Error 
Condition 
Failure 
Mechanism 
Host Action 
SCTE POD 
Module Action 
Comments 
POD READY 
signal does not 
go active 
POD 
Host either: 
 
Reports error 
message 
 
Retries 
PCMCIA resets 
up to two times 
and then 
reports error 
message 
 
Reports error, 
but continues to 
perform 
PCMCIA resets 
None 
Host reports 
error to user
1
 
Host reads 
incorrect CIS 
values 
POD 
Host reports error 
message 
None 
Host reports 
error to user
1
 
Host writes 
incorrect 
TPCE_INDX 
value to POD 
configuration 
register 
Host 
None 
POD cannot 
perform any 
action 
Host detects a 
failure #4 and 
reports error 
to user
1
 
Host sets data 
channel RS bit, 
but POD fails to 
set FR bit within 
5 second timeout 
POD 
Host either: 
 
Reports error 
message 
 
Retries 
PCMCIA resets 
up to two times 
and then 
reports error 
message 
 
Reports error 
and continues 
to perform 
PCMCIA resets 
None 
Host reports 
error to user
1