Cisco PowerKEY CableCARD Module 802 Mode D'Emploi

Page de 52
 
 
Configure the DNCS for CableCARD and M-Card Support 
78-4011765-01 Rev C 
 
Stopping and Restarting the siManager Process 
The System Information Manager (siManager) generates SI tables. The SI tables 
provide service information to CableCARD modules and hosts, M-Card modules 
and hosts, set-top CableCARD hosts, and set-top M-Card hosts. To finish updating 
your system in order to support OpenCable, you must stop and restart (bounce) the 
siManager process by completing the following steps: 
Important! This process will temporarily inhibit DHCTs from booting; however, 
DHCTs that are already operational will not be impacted. 
1  From the DNCS section of the DNCS Administrative Console Status window, 
click Control. The DNCS Control window opens. 
 
2  From the list of processes, select siManager
3  Click Process and select Stop Process. A confirmation window opens. 
 
4  Click Yes to confirm that you want to stop the siManager process. The indicator 
next to siManager turns red to identify that the process is stopped.