Cisco Cisco D9824 Advanced Multi Decryption Receiver Guide De Montage
Chapter 3 Installation
24
OL-29015-01
Changing the Relay Mode for Alarm Monitoring
The Alarm relay is a program relay that can be configured to provide programmed
responses for alarms, warnings, cue trigger states for ad-insertion equipment, or a
cue tone output for connection to ad-insertion equipment. As a default, the Alarm
Relay is configured for Alarm mode.
1 On the front panel menu, go the Main: Setup: Outputs, and select Cueing.
2 Use the down arrow key to scroll through the menu to Relay Mode.
3 Change the state to Alarm and press the Select key to save the new setting. As a
responses for alarms, warnings, cue trigger states for ad-insertion equipment, or a
cue tone output for connection to ad-insertion equipment. As a default, the Alarm
Relay is configured for Alarm mode.
1 On the front panel menu, go the Main: Setup: Outputs, and select Cueing.
2 Use the down arrow key to scroll through the menu to Relay Mode.
3 Change the state to Alarm and press the Select key to save the new setting. As a
result, the rear panel connector pin states will change to that shown in the table
below for Alarm mode.
below for Alarm mode.
Connector
Normally
closed pin
closed pin
Common pin Normally open
pin
Relay Mode
11
10
15
Trigger
15
10
11
Alarm (default)
Note: A normally closed state implies the state when power is applied to the relay in
a normal operating state, without a trigger or alarm condition present.
a normal operating state, without a trigger or alarm condition present.