Cisco Cisco Surge-Gap Passives Guide De Montage

Page de 52
Chapter 2    Installing the Tap/Passive 
 
 
 
Tools and Torque Specifications 
Tools Required 
Before you start, make sure you have the following tools. 
 
Tools 
Used to. . . 
Appropriate coaxial cable coring tool 
Prepare feeder cable ends 
3/8-in. hex wrench, or nut driver 
Tighten strand clamp bolts and retainer bolts 
1/2-in. or 3/8-in. wrench, or nut driver 
Remove and replace cable end plugs 
3/16-in. hex nut driver 
Tighten seizure screws 
Small flat-end screwdriver 
Rotate seizure mechanism 
Propane torch, or equivalent 
Apply heat shrink 
Wire cutters 
Cut cable/center conductor 
Sharp knife 
Trim 
Torque wrench in in-lb 
(0 in-lb to 250 in-lb minimum) 
(0 Nm to 28.2 Nm minimum) 
Tighten seizure screws, connectors, and 
retainer bolts 
7/16-in. wrench 
Tighten house drop F-connector 
15/16-in., 1-in., and 1 1/8-in. wrenches 
Tighten connectors for feeder cable 
Sizes may vary depending on manufacturer 
and connector style. 
Grounding wire assembly, part number 
569533 (hot install only) 
Prevent electric shock and equipment damage. 
Certain components can deliver an electrical 
shock 
Room temperature vulcanizing (RTV) 
silicone 
Seal connections 
 
 
 
Torque Specifications 
The following are recommended torque specifications for the tap and passive. 
 
Part 
Torque Specification 
Strand clamp bolt 
30 in-lb to 40 in-lb (3.4 Nm to 4.5 Nm) 
 
10 
OL-31976-01