Cisco DNCS System Release 2.7 3.7 4.2 Références techniques

Page de 16
4011319 Rev C 
 
 
 
Configure Unencrypted Transport Streams 
 
4  Power on the PC and activate a ProComm or HyperTerminal window using the 
following modem connection settings: 
 
9600 baud 
 
1 stop bit 
 
No parity 
 
8 data bits 
 
No flow control 
5  Press the Enter key. A QAM> prompt appears. 
6  Type pidmode 1 and press Enter to enable passthru mode. 
7  Repeat steps 1 through 6 for any additional QAMs. 
8  Go to 
Setting Up Non-Cisco Digital Sources (on page 7). 
 
Setting Up Non-Cisco Digital Sources 
Complete these steps to set up a non-Cisco digital source. 
1  On the DNCS Administrative Console, click the DNCS tab. 
2  Click the System Provisioning tab. 
3  Click Source. The Source List window opens. 
 
4  Does the source already exist? 
 
If yes, click once on the row containing the source, then go to step 10. 
 
If no, go to step 5.