Cisco Cisco 1 GHz GainStar Amplifier Guide De Montage
4034994 Rev B Technical Information 6-3
Forward Cable Equalizer, Continued
862 MHz Forward Cable Equalizer Loss Table
Typical Insertion Loss(dB)at Various Frequencies(MHz)
EQ
Value
(dB)
Value
(dB)
Part
Number 54 77 86 550 600 650 750 862
Number 54 77 86 550 600 650 750 862
0
0.4 0.4 0.5 0.2 0.2 0.1 0.1 0.3
1
1.4 1.4 1.4 0.6 0.5 0.5 0.4 0.4
2
2.4 2.4 2.3 0.9 0.9 0.8 0.6 0.5
3
3.4 3.3 3.3 1.3 1.2 1.1 0.8 0.5
4
4034450
4.4 4.3 4.3 1.6 1.5 1.3 1.0 0.5
5
5.8 5.6 5.6 1.8 1.6 1.3 0.9 0.5
6
6.8 6.6 6.5 2.0 1.7 1.4 0.9 0.5
7
7.7 7.5 7.4 2.3 2.0 1.6 1.0 0.5
8
8.7 8.4 8.3 2.5 2.2 1.7 1.0 0.5
9
4034451
9.6 9.4 9.2 2.7 2.3 1.8 1.1 0.8
10
10.6 10.3 10.2 3.6 3.1 2.6 1.7 0.8
11
11.5 11.2 11.1 3.7 3.3 2.7 1.7 0.8
12
12.5 12.1 12.0 4.0 3.5 2.8 1.7 0.8
13
13.5 13.1 12.9 4.2 3.6 3.0 1.9 0.8
14
4034452
14.4 13.9 13.7 4.4 3.7 3.1 1.9 0.8