Cisco Prisma II 1310 nm HDTx Transmitters Guide De Montage
3-16
Operation Using the ICIM
78-713378-01 Rev C
Configuring the Reverse Receiver Using the ICIM
Configurable Parameters
Configurable parameters for the Prisma II Reverse Receiver are listed below.
Continued on next page
Control
Function
Values
Default
Mute1,
Mute2
Force Mute. Muting of the RF signal and
removal of power to the amplifier only if the
Enable control is on for this particular side.
ON or OFF
OFF
Enable1,
Enable2
Enables or disables unit operation, i.e.,
muting enabled and no alarm capability
ON or OFF
ON
Alarm1,
Alarm2
Force Alarm. Alarm relay is manually
overridden only if the Enable control is On.
This sets a particular side to alarm as if there
was an internal alarm, i.e., Alarm output
high, muting on as per Force Mute above
ON or OFF
OFF
Master1,
Master2
Configures the module as master or slave. If
set to Master, the unit is controlled only by
the Enable control above. If set to Slave, the
unit is controlled by a combination of the
Enable control and the external input
CNT_IN_1 or CNT_IN_2.
ON or OFF
ON
Atten1
Atten2
Sets the attenuation level of the output RF
signal.
Decimal number
between 0 and 20
dB, increments of
0.5 dB
0 dB
NomPwr1,
NomPwr2
The nominal input optical power level, in
dBm.
Decimal number
between –20 and
0 dBm,
increments of 0.5
dBm
0 dB