Cisco Cisco OptoStar II Driver Amplifier Guide De Montage

Page de 82
Operating using ICIM LCD, Continued 
Sub-Menu 2 -- Optical Output Information 
The illustration below shows sub-menu 2 of the OptoStar II 1550 nm optical 
amplifier module - Optical Output Information. 
 
The optical output information sub-menu includes options to set the optical 
output power alarm threshold and a reading of the optical output parameters. 
Optical output parameters include: optical output power and optical amplifier 
type. Optical output power displays the optical output power of one port when 
there are multiple optical output ports.   
Optical amplifier modules with different models have different optical power 
alarm thresholds. The default lower limit of the alarm threshold is (standard 
value - 4.0) dBm; and upper limit is (standard value + 1.0) dBm; taking 8x17 
optical amplifier as example, the range of optical power alarm threshold is + 13 
dBm ~ + 18 dBm; the cursor stays in the “Low” field.   
• 
To configure the lower limit of the optical alarm threshold (minimum output 
power is no less than (standard value – 4.0) dB) 
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm;   
3.  Press ► button to move the cursor to “Set”; 
4.  Press SET button to save the configuration. 
• 
To configure the upper limit of the optical alarm threshold (maximum output 
power is no more than (standard value + 1.0) dB) 
1.  Press ▼ button to move the cursor in the “High” field; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
4.  Press ► button to move the cursor to “Set”; 
5.  Press SET button to save the configuration. 
3-8 
 
Operation 
OL-29666-02