Cisco Cisco OptoStar II Driver Amplifier Guide De Montage

Page de 75
Console-Module Control Interface, Continued 
Setup Parameters 
The table below lists the parameter settings of the OptoStar II forward driver 
amplifier module.   
Setup Parameters 
Description 
Factory Default 
RF Input Alarm 
Threshold   
Shows/sets upper limit and lower 
limit of RF input alarm   
Lower limit: 10 
dBmV 
Upper limit: 20 
dBmV 
Output Signal 
Slope Settings 
Output signal slope settings (range: 
0~9 dB) 
0 dB 
Output Signal Gain 
Settings 
Output signal gain settings (range: 
-9~0 dB) 
0 dB 
Channel Load 
Shows/sets analog channel 
number, QAM channel number, 
and delta level (dB) 
Analog channel 
number: 59 
QAM channel 
number: 53 
Delta level: 6. 0 dB 
Alarm ON/OFF 
Shows/sets module alarm status: 
ON/OFF 
Alarm status: ON 
 
Continued on next page 
 
3-38 
 
Operation 