Cisco Cisco OptoStar II Driver Amplifier Guide De Montage

Page de 67
Operating using Console Software, Continued 
The table below lists the basic parameters of the OptoStar II optical switch 
module. 
Basic Parameter 
Description 
Module Name and Firmware 
Version 
Shows the module name and its firmware 
version 
Optical Input Power in Channel 
A/B 
Shows optical input power in Channel A/B 
(dBm) 
Module Temperature 
Shows the current module temperature (°C) 
S/N 
Shows module serial number 
Rack ID 
Shows the ID of the rack where the chassis 
is placed 
Slot ID 
Shows the ID of the slot where the module 
is placed 
Alarm Code 
Shows the current module alarm code; See 
Alarm Code List (on page 3-13) 
 
Setup Parameters 
The table below lists the setup parameters of the OptoStar II optical switch 
module. 
Setup Parameters 
Description 
Factory Default 
Optical Alarm 
Threshold 
Shows/sets optical alarm 
upper limit and lower limit 
Lower limit: - 15 dBm 
Upper limit: + 25 dBm 
Auto/Manual 
Switching Mode 
Selection 
Shows/sets Auto/Manual 
switching mode 
Auto switching mode 
Channel A/B Selection  Shows/sets channel A/B 
Channel A 
Optical Wavelength 
Setup 
Sets input optical wavelength 
1310nm (1270nm ~ 
1410nm) 
Alarm ON/OFF 
Shows/sets module alarm 
status: ON/OFF 
Alarm status: ON 
 
 
 
 
 
OL-29670-02 
Operation 
3-19