General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-16) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
Low Optical 
Input Power 
 
Low optical output power 
in reverse transmitter 
module of the node 
 
Connectors between the 
reverse transmitter and the 
optical splitter mismatch   
 
Connectors between the 
reverse transmitter and the 
optical splitter contain 
dusts or contaminants 
 
Splitter failure 
 
Optical link loss exceeds the 
designed value 
 
Fiber connector and the 
reverse receiver connector 
mismatch 
 
Check the optical output 
power in reverse 
transmitter of the node 
 
Check whether all the 
optical connectors match 
 
Make sure all the mating 
surfaces of the fiber are 
clean 
 
Check splitter for signal 
 
Check whether the 
optical input power is 
between -16dBm and 
+2dBm with an optical 
power meter 
 
If the problem persists, 
contact the manufacturer 
for servicing 
High Optical 
Input Power 
 
High optical output power 
in reverse transmitter of the 
node 
 
Link connection failure 
 
Check the optical output   
power in reverse 
transmitter of the node 
 
Ensure the link 
connection is correct 
 
If the problem persists, 
contact the manufacturer 
for servicing 
 
 
Continued on next page 
 
 
4-4 