Site Requirements,
 Continued 
Electrical Power  
The Prisma II modules receive electrical power from the Prisma II Chassis via the 
Prisma II power supplies.  For specific information concerning chassis power 
requirements and power supply installation, see the guide that was shipped with the 
chassis, the Prisma II Chassis Installation and Operation Guide, part number 713375.   
Chassis Slot Availability 
The Prisma II bdr 2:1 Dual Receive Processor is a double-wide module.  It may only 
be installed in slots 5 through 16.  Slots 15 and 16 are usually reserved for the 
Intelligent Communications Interface Module (ICIM), if installed.  However, if an 
ICIM is not installed in slots 15 and 16, this processor or any other module(s) could 
be installed in those slots.   
Power Supply Installation Slot Restrictions (Slots 1 through 4 ) 
Important:  Slots 1 through 4 of the chassis are reserved exclusively for the Prisma II 
primary and redundant power supplies.  If a redundant power supply is not 
installed, this module must not be installed in the redundant power supply slots.   
If only one power supply is installed, a Prisma II Power Supply Blank, part number 
716308, must be installed in the unused power supply slots.   
Front and Rear Access Chassis Styles 
The chassis has power inlets, RF input and output ports, and other connectors that 
are located on the connector interface panel.  This panel may be located on the front 
(front access) or rear (rear access) of the chassis, depending on the system you have 
purchased.  Regardless of their location, these connections are labeled the same, 
serve the same function, and are made in the same manner. 
For more detailed information concerning the connector interface panel, see the 
guide that was shipped with the chassis, the Prisma II Chassis Installation and 
Operation Guide, part number 713375.