Brother RJ-3050 Guide De Référence

Page de 129
ESC/P Command Reference 
 
- 110 - 
5. Control Command Details 
ESC iXj2 
Select default international character set 
ASCII: 
ESC 
n1 
n2 
n3 
Decimal: 
27 
105 
88 
106 
50 
n1 
n2 
n3 
Hexadecimal:  1B 
69 
58 
6A 
32 
n1 
n2 
n3 
Parameters 
n1: 01h (Fixed) 
n2: 00h (Fixed) 
00h≤n3≤0Dh, 40h 
Description 
  Selects the default international character set. 
n3=00h:  U.S.A. (*
Manufacturer’s default) 
n3=01h:  France 
n3=02h:  Germany 
n3=03h:  U.K. 
n3=04h:  Denmark I 
n3=05h:  Sweden 
n3=06h:  Italy 
n3=07h:  Spain I 
n3=08h:  Japan 
n3=09h:  Norway 
n3=0Ah:  Denmark II 
n3=0Bh:  Spain II 
n3=0Ch:  Latin America 
n3=0Dh:  South Korea 
n3=40h:  Legal 
  This command is a static command. 
Remarks 
  Invalid if n3 is a value outside of the allowable range