Samsung RF23J9011SR French Door Refrigerator with Triple Cooling, 22.5 cu.ft Manuel D’Utilisation

Page de 108
English - 16
Snap Rings included with the refrigerator:
1 mm
1.5 mm
2 mm
2.5 mm
HOW TO ADJUST THE DOOR GAP
If the gap between the left and right fridge 
compartment doors is not even.
•  You can adjust the gap by 
turning the bolt at the top 
right of the cold storage 
compartment door. 
•  Do not turn the bolt too far.  
You can break it.
1.  With the doors closed, remove the 3 screws 
holding the top cover using a Phillips 
screwdriver, and then lift it off together with the 
connected cables.
2.  Turn the bolt with a 4 mm 
hexagonal L-wrench to 
adjust the gap.
3.  Turn the bolt clockwise to ( 
 ) widen the 
gap. Turn the bolt counterclockwise ( 
 ) to 
narrow the gap.
INSTALLING THE WATER 
DISPENSER LINE
A water dispenser with a filter is one of the helpful 
features on your new refrigerator. 
To help promote better health, the water filter 
removes unwanted particles from your water. 
However, it does not sterilize or destroy 
microorganisms. 
You may need to purchase a water purifying 
system to do that. 
The water line also connects to the ice maker. 
For the ice maker to operate properly, water 
pressure of 20 ~ 125 psi is required. 
If the refrigerator is installed in an area with low 
water pressure (below 20 psi), you can install a 
booster pump to compensate for the low pressure. 
After you have connected the water line, make 
sure the water storage tank inside the refrigerator is 
properly filled. 
To do this, press the water dispenser lever until the 
water runs from the water outlet.
•  Water line installation kits are available at 
extra cost from your dealer.  
We recommend using a water line 
installation kit that contains copper tubing 
and a 6 mm (¼”) compression nut.
•  Use the new hose-sets supplied with the 
appliance only. Do not re-use an old hose set. 
Connecting to the water supply line
1.  First, shut off the main water 
supply.
2.  Locate the nearest cold water drinking line and 
install the pipe clamp and shut off valve.
Pipe clamp
Cold water line
Shut off valve
DA68-03194D-04.indb   16
2016. 3. 31.   �� 10:19