Spot-out monitoring
Spot-out Monitoring has nothing to do with Live Screen Output, it monitors the full screen of a
certain channel. If you select the Monitoring in the MENU, the one channel among CH1 ~ CH16
is output with a Spot-out or channels are output one by one at an interval as Auto Sequence
Mode in the Live Mode. Live screen icon does not appear in the spot-out monitoring. 
The interval is as same as the Auto Sequence time in the Live Mode. If the Spot-out Event
Monitoring is On, it is possible to see the event channel with Spot-out. In case of simultaneous
event occurrence at more than one channel, the lowest numbered event channel has the first
priority to be spotted out.
Concerning occurrence of a fan error, if it is a long-term problem it will shorten the lifespan of
the product.
When a fan error occurs, we ask that you please contact the service center.
Caution
Caution
If the built-in HDD is not connected, or it operates with power applying in error,(
)
indicating “built-in HDD error” is displayed at the top of left.
At this time,
(1) Live screen mode
(2) Monitoring mode by Smart Viewer
operate only and the other functions including recording, search, playback, menu
setup, and PTZ do not operate.
If the above problem is occurred, be sure to contact a service center to settle the problem.
Caution
Caution
If the fan in a set does not operate or has a problem, a fan  error message pops up in the live
screen as below picture. And the fan error icon        appears at the top of left . 
If you notice that this is happening in your unit, check whether your fan is running or not. 
The icon at the top of left disappears automatically if the fan recovers its operation.
Fan Information
A error occurs in the fan. 
Refer to the manual.
Note
Note
In the live screen, you can select a spot channel as below.
- When you press the stop button and press one button out of channels 1-16, then that 
channel is set up as the spot-out channel.
- When you press the stop button and then the mode button within 2 seconds, spot-out is set
as change screen mode.