Apple performa 400 series Instruction De Maintenance
Troubleshooting
Symptom Charts/Miscellaneous - 15
System seems to boot;
then message “Finder
is old version”
displays
Install newer version of system software.
System
intermittently doesn’t
power on
1 Check cables.
2 Plug monitor directly into wall socket. Verify that monitor
has power.
3 Try known-good keyboard and ADB cable.
4 Replace power cord.
5 Check batteries. See “Battery Verification” in Additional
Procedures.
6 Replace logic board. Retain customer’s SIMMs.
Monitor raster width
too narrow
Refer to Adjustments section in appropriate Monitor manual for
horizontal size (width) adjustment.