Juniper CBL-PWR-10AC-STR-JP Manuel D’Utilisation

Page de 232
Related
Documentation
Replacing an AC Power Cord
M7i Router DC Power Specifications and Requirements
M7i Chassis Grounding, Connection, and Cable Specifications
To ground a router, connect a grounding cable to earth ground and then attach it to the
chassis grounding point on the rear of the chassis.
summarizes the specifications for the groundingcable, which you
must supply.
Table 22: Grounding Cable Specifications
Maximum
Equal
Length
Quantity and Specification
None
One 14-AWG (2.08 mm
2
) single-strand-count wire cable
shows the location of the grounding point on the upper left side of
the M7i router above the power supplies.
CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding cable that you supply. A cable with an incorrectly
attached lug can damage the router.
171
Copyright © 2012, Juniper Networks, Inc.
Appendix D: Power Guidelines, Requirements, and Specifications for the M7i Router