The summer-name can be up to 32 alphanumeric characters long, with 
no spaces. The start and end dates and times are optional. If you do not 
specify a start and end time, MSS implements the time change starting at 
2:00 a.m. on the first Sunday in April and ending at 2:00 a.m. on the last 
Sunday in October, according to the North American standard.
To set the summertime period to PDT (Pacific Daylight Time) and use the 
default start and end dates and times, type the following command:
WX1200# set summertime PDT
success: change accepted.
Displaying the Summertime Period
To display the summertime period, use the following command:
display summertime
For example, to display the summertime period, type the following 
command:
WX1200# display summertime
Summertime is enabled, and set to 'PDT'.
  Start  : Sun Apr 04 2004, 02:00:00
  End
 : Sun Oct 31 2004, 02:00:00
  Offset : 60 minutes
Recurring : yes, starting at 2:00 am of first Sunday of 
April and ending at 2:00 am on last Sunday of
October.
(For information about the fields in the output, see th
Wireless LAN 
Switch and Controller Command Reference
.)
Clearing the Summertime Period
To clear the summertime period, use the following command:
clear summertime