Venting
32
Venting through a Vent Hose 
The vent hose expelling the hot air should have a 100 mm diameter and 
be no longer than 4 meters. Avoid bends in the vent hose as this will 
reduce the air flow. The maximum length of the vent hose may be: 
4 meters with 0 bends, or 
2 meters with 2 bends. 
If the vent hose is to be permanently installed to the outside, a wall box 
or suitable cover should be used on the outside wall. 
Example:  
A vent hose (Part number: 899647000010/1) and wall box (Part 
number: 899647000020/0) are available from your local AEG Service 
Force Centre. 
Ensure the vent hose is not squashed. The drying efficiency of the 
tumble dryer will be affected and may cause the safety cut outs to 
operate. 
Warning! The vent hose must not be connected to a flue pipe or 
chimney designed to carry the exhaust from a fuel burning heating 
appliance.